Home
Industries Projects Blog About Contact
Get a Free Quote Call +1 469 887 6400
Plant and Process

Plant and industrial scan to BIM for retrofits that cannot afford surprises

Shutdown windows are short and expensive. We model your process piping, structures and equipment as they are today, so new tie ins land first time and the plant restarts on schedule.

Named project lead Fixed price, fixed date

Service snapshot

What a typical engagement looks like
Typical LODLOD 300 to LOD 400
SectorsOil and gas, chemical, food, energy, water
SoftwareRevit, AutoCAD Plant 3D, IFC
DeliverablesRVT, DWG, IFC, NWD, isometrics
IncludesTie in point verification
Request pricing for this service

No obligation. Most quotes go out within 24 hours.

Overview

In a live plant, a measurement error costs a day of production

Process facilities change constantly. Lines get rerouted, valves get relocated, supports get added. P and IDs stay accurate but the physical layout drifts, and that drift is what breaks a tie in.

We model from scan data with pipe sizes, spool positions and support locations captured as built, and we work in the formats your engineering contractor already uses. Before fabrication starts, we usually run the model through clash detection to confirm every tie in is clear.

  • Pipe runs with real diameters, routes and supports
  • Equipment, skids, tanks and vessels in true position
  • Steel racks, platforms, stairs and access routes
  • Tie in points verified before fabrication starts
Process model · Pipe rack 3
Why choose us

The tie in accuracy a shutdown budget actually depends on

In a live plant, the cost of being wrong is measured in a closed line, not a change order.

01
Tie ins measured, not estimated

Coordinate and tolerance reported per connection

This is what stops a spool arriving short on a shutdown that cost you a booked crew and a closed line.

02
LOD 400 as a standard offer

Fabrication level detail available on every project

Fittings, valves and connection detail suitable for spool drawings, not just a layout diagram.

03
Shutdown backwards planning

Programme built from your outage date, not ours

Verified data reaches your fabricator with time to spare instead of the week before the plant goes down.

04
Insulation outer face modeled

Both pipe and insulation dimension captured

Clearance decisions depend on the outer face, not the nominal pipe size, so we model both.

What you get

What the plant package delivers

Built for engineering contractors working to a shutdown clock.

Process piping model

Lines modeled with diameter, route, insulation outline, valves, flanges and support positions.

Equipment and skid model

Vessels, pumps, tanks, heat exchangers and packaged skids placed in their measured positions.

Structural steel model

Pipe racks, platforms, walkways, stairs and ladders modeled with real section sizes.

Tie in verification

Every proposed connection point checked against the scan with a measured coordinate report.

Clash and access study

Clash testing plus crane, lifting and maintenance access routes tested against the model.

Piping isometrics

Isometric drawings generated for fabrication where the project requires them.

Scope of work

What we model in a plant environment

Scoped area by area so you can start with the zones affected by the next shutdown.

Included in every project

  • Above ground process piping and fittings
  • Valves, flanges, instruments and inline items
  • Pipe supports, shoes, guides and anchors
  • Storage tanks, vessels and columns
  • Pumps, compressors and rotating equipment
  • Heat exchangers and packaged skids
  • Structural steel racks and platforms
  • Cable trays, conduit and electrical containment
  • HVAC and utility services in process buildings
  • Access routes, stairs, ladders and handrails
Scope itemWhat we deliverTypical use
PipingRouted lines with size, spec, supports and inline itemsTie in design and spool fabrication
EquipmentVessels, pumps and skids with nozzle positionsReplacement and relocation planning
SteelRacks, platforms and access structuresLoad checks and modification design
VerificationCoordinate report on every tie in pointFirst time fit at shutdown
Working to a shutdown date. Tell us the window at quote stage. We schedule plant projects backwards from the shutdown so verified tie in data is in your fabricator hands with time to spare.
How it works

How a plant project runs

Safety planning and access coordination are part of the job, not an afterthought.

Area scoping

We break the facility into zones and agree which lines, equipment and structures are in scope for each one.

Scan review

Coverage is checked against the scope, with attention to congested areas where occlusion is likely.

Model build

Piping, equipment and steel are modeled by discipline against the registered cloud.

Tie in verification

Proposed connection points are measured, reported with coordinates and issued for fabrication.

Coordination

Clash and access studies are run, then the federated model is handed to your engineering team.

Why clients pick us for this

Shutdown focused

Programmes planned backwards from your window.

Fabrication accurate

Tie in points measured and reported, not estimated.

Live site experience

Used to working around operating facilities.

Request a fixed price quote
Case study

Sixty two tie ins verified before a ninety six hour shutdown

Industrial · Rotterdam

The challenge

A food processing plant needed to tie new process lines into an existing piping network during a single 96 hour shutdown window, with no room for a tie in to be wrong once fabrication started.

What we did

We modeled the existing piping and steel to LOD 400 from scan data, measured all 62 proposed tie in points against the registered cloud and issued a coordinate report the fabricator used directly for spool drawings.

The result

62 tie ins verified

Every one confirmed within tolerance before fabrication began

Zero spools rejected

The fabricator returned zero spools during the shutdown

96 hour shutdown held

Plant restarted on schedule with no extension

"Sixty two tie ins, every one within tolerance. Our fabricator did not send a single spool back. That has never happened before on a shutdown this size."
PVP. van DijkEngineering Manager, Process Facility
Questions

Plant and Industrial BIM questions we hear most

Straight answers so you can scope your project with confidence.

Both. Revit suits buildings and mixed facilities, Plant 3D suits process heavy scopes with spec driven piping. We will recommend the right one for your project and can deliver IFC either way.

Yes, where the model is built with a piping specification applied. We confirm the spec at the start so isometrics can be generated cleanly rather than drafted by hand.

Congestion is where occlusion hurts most. We identify shadowed zones during the scan review, request supplementary scans where needed, and mark anything modeled from partial data.

Yes, and it is one of the most valuable things we do. Each tie in gets a measured coordinate, a photo reference and a tolerance note, which is what stops a spool arriving 40 mm short.

Yes. Insulated lines are modeled with both the pipe and the outer insulation dimension, because clearance decisions depend on the outer face.

Start your project

Send your scan data today. Get a quote tomorrow.

Tell us the building, the area and the level of detail you need. We will come back with a fixed price and a firm delivery date within 24 hours.